China manufacturer of magnetic ballasts for metal halide flood lights & hps flood lights

Email:
Support

James  Electronic


Email: Sales@ballastrus.com
URL : www.ballastrus.com

Home » Faq
  • [2013-12-10]
    The 600 Watt high pressure sodium lamps grow lighting systems come complete with everything you need to start growing your plants; including the bulb, ballast, reflector, socket assembly, 15' lamp cord, wire hooks for hanging the reflector and instructions. They are pre-wired and take only a couple of minutes to setup. All grow light ballast assemblies feature multi-tap transformers. This means that you can switch them from 110/120V to 220/240V with just on switch.600 Watt HPS High Pressure Sodium Grow Light Bulb (Horticulture Grow Model) (1X Bulb) Lumens: 90,000 / 2000 K / Mogul E39 / Bulb: TD15 / OP: Universal / ALLOW 2 MINUTES TO FULLY POWER UP Spectrum: 80% Red 650 (NM) / 20% Blue 469 (NM) ANSI: S106 (Electronic or Magnetic Ballast Compatible) / LAMP VOLT: 110 / CURRENT: 6.1 - 6.2 24,000 HOUR AVERAGE RATED LIFE/ TCLP COMPLIANT / ALLOW 30 MINUTES FOR RESTRIKE...
  • [2013-12-10]
    1000 Watt HPS High Pressure Sodium Grow Light Bulb (Horticulture Grow Model) (1XBulb) Lumens: 140,000 / 2000 K / Mogul E39 / Bulb: E25 / OP: Universal / ALLOW 2 MINUTES TO FULLY POWERED UP Spectrum: 80% Red 650 NM / 20% Blue 469 NM ANSI: S52 (Electronic or Magnetic Ballast Compatible) / LAMP VOLT: 250 / CURRENT: 4.7 24,000 HOUR AVERAGE RATED LIFE/ TCLP COMPLIANT / ALLOW 30 MINUTES FOR RESTRIKE High Output HPS Lamps are High Pressure Sodium lamps designed to deliver 10% more light than standard HPS lamps. This extremely energy-efficient plant grow lamp provides more energy which is essential for optimized photosynthetic response. 10% more light than a standard HPS lamp Red output for stem elongation and flowering Long life, economical Ideal companion for Metal Halide Conversion Lamps General Characteristics Watts: 1000 Lamp Description: SL.1000W.U25.2.1K Ballast Type: HPS Initial Lumens: 140,000 PAR Watts: 358 Life Hours: 24,000 Operating Position: Universal Base type: Mogul (E39) ANSI Code: S52 Bulb Shape: E25 Photometric Initial Lumens: 150000 Lumens Per Watt: 146 Lamp Lumen Depreciation: .90 (90%) @ 9600 hours Correlated Color Temperature: 2100 Chromaticity Coordinated (CIE-x,y): .512 .420 Color Rendering Index: 22...
  • [2013-12-09]
    Nearly all applications, including streetlights and parking lot lights, will use a standard magnetic core and coil ballast. Their high heat tolerance and wide array of voltages and configurations make core and coil the most popular of HPS ballasts. To aid in installation and reduce labor costs, almost all core and coil ballasts we carry include pre-wired capacitors and ignitors. High Pressure Sodium Lamp based Ballasts are a great way of limiting or controlling the amount of input that is consumed by the lighting installation of High Pressure Sodium lamps it fixed to. These ballasts use compressed High pressure sodium to produce an arc to generate heated energy to for the lamps fixtures and enable lighting of High Pressure Sodium Lamp derived installation. High Pressure Sodium Ballasts are highly favored for outdoor lighting, gardens and indoor gardening. Such a wide color spectrum is difficult to produce in alternative lighting options, creating a niche consumer market for this kind of lighting....
  • [2013-12-08]
    High pressure sodium lamp is a gas-discharge lamp that uses sodium in an excited state to produce light. There are two varieties of such lamps: low pressure and high pressure. Low-pressure sodium lamps are the most efficient electrical light sources, but their yellow light restricts applications to outdoor lighting such as street lamps.[1] High-pressure sodium lamps have a broader spectrum of light than the low pressure, but still poorer color rendering than other types of lamps. Low pressure sodium lamps only give monochromatic yellow light and so inhibit color vision at night. Once the lamp is selected, the next step is to select the ballast that will be used to drive it. When putting together a HPS ballast lighting system, it is very important to match the ballast to the lamp(s). An easy way to do this is by using the ANSI designation. For example, when using a lamp designated M-57, look for a ballast with that same designation....
  • [2013-12-08]
    Metal halide ballasts are required to start the lamp, regulate the lamp starting and lamp operating currents, and provide appropriate sustaining supply voltage. (See "What are warm-up and restrike times for metal halide lamps?") Metal-halide lamps have high luminous efficacy of around 75 - 100 lumens per watt,which is about twice that of mercury vapor lights and 3 to 5 times that of incandescent lights, Lamp life is 6,000 to 15,000 hours.and produce an intense white light. As one of the most efficient sources of high CRI white light, metal halides are the fastest growing segment of the lighting industry.They are used for wide area overhead lighting of commercial, industrial, and public spaces, such as parking lots, sports arenas, factories, and retail stores, as well as residential security lighting and automotive headlamps (xenon headlights)....
  • [2013-12-06]
    High pressure sodium lamp and metal halide lamp by high -intensity gas -emitting light , high luminous efficiency, long service life. However , due to its supporting ballast design theory followed traditional magnetic ballast , bulky , heavy, more importantly, its power consumption is high , some more than 30% of rated power bulbs waste a lot of valuable energy, apparently incompatible with efficient light sources , it is necessary to retrofit designs. We all know that traditional magnetic ballast is E -shaped core made ​​of silicon steel stack and subsequently sets made ​​with enameled circle around made ​​. Since the E -shaped magnetic steel sheet uneven lines , combined with its E -shaped steel sheet mechanical properties is limited , it is impossible to improve the magnetic flux density , and therefore , in order to reduce eddy current loss of the E-shaped silicon steel , tend to be very thin silicon steel , silicon steel be insulated sheet , so the duty ratio rising core is bound to increase in the core area of ​​the design needs to be compensated , and a corresponding increase in wire along the perimeter , increasing material loss silicon steel and enameled wire , increasing the volume and weight of the ballast , the ballast itself increased copper loss and iron loss , an increase of its losses. Given the overall shape of the ballast section of the iron core loss , size, window size , the magnetic flux density , the silicon steel sheet thickness , and other factors related to the mains frequency . Therefore, the traditional characteristics of the E-shaped structure ballast , ballast after reshaping how to shorten the magnetic circuit , reducing the core volume , reduce the loop length , narrow space , reducing ballast own loss , improve efficiency and heat our ability to design guidelines . Further , the magnetic ballast loss of the ballast is also proportional to the volume of the ballast core . When the cross-sectional area and the core values ​​Bm be taken , as far as possible will be designed to be a minimum core volume , the smaller the size , the iron loss is correspondingly smaller. Core volume can be approximated as a core cross-sectional area of ​​the path length L of the product....
  • [2013-12-05]
    Starting voltage is superimposed by a HID ignitor pulse transformer built-generated. It mains voltage rises to the high pressure needed to start the lamp, while the boot process is controlled by intelligent circuit. This means that the company's Modular ignitor system with high reliability and repeatability of the pulse, the working voltage will not be affected by fluctuations in the mains. Standard stacking ignitor has excellent durability and reliability, it can effectively run at 220V-240V and 380V-440V two voltages, while extremely low temperature, applied with heat demanding applications. When the mains voltage drops below 198V when (threshold voltage), the company is still able to ignitor the lamp to ensure a smooth start. After the lamp start lighting ignitor off to avoid damage to the lamp. Use high-quality, high-precision components, so turn-off voltage of up to 185V. Temperature is an important parameter affecting the ignitor range of applications, the company's flip-flop has a very low temperature, which will bring more convenience lighting....
  • [2013-12-05]
    HID magnetic ballasts is inductively gas discharge lamp ballasts. HID is High intensity Discharge HID abbreviation, mercury, sodium, gold, Xenon collectively, the mercury lamp, sodium lamp, metal halide lamp, a xenon lamp. A ballast inductor core inductor, the inductor when the nature of the current in the coil is changed, the change is caused in the magnetic flux in the coil, thereby generating an induced electromotive force opposite to the direction of the current, thereby hampering the current changes. High -intensity discharge lamps require ballasts to work with . Magnetic ballasts use inductance principle , to control the lamp current and power to take control of the lamp current and power , in order to ensure its high luminous efficiency and working properly. Inductive ballast must match the light source used , to ensure it is working properly....
  • [2013-12-05]
    According metal halide working substance named . Sodium scandium metal halide which is the working substance is a halide of scandium and sodium ; sodium thallium and indium in the metal halide lamp is the working substance is a halide of sodium , thallium, indium and other metals . This is the typical metal halide in the two series . Scandium sodium lamp series is now widely used in our country , but also the so-called American Standard series of lights. Sodium thallium , indium series of lights is widely used in Europe , the so-called European standard lamps. European standard metal halide lamps: 1,4000-4500K Color Temperature 2 , CRI , Ra65-70 3 , high luminous efficiency , long life and reliable performance 5, for flood lighting, outdoor billboards , stadium lighting, etc....
  • [2013-12-04]
    1 , energy efficient :Magnetic ballast operating frequency is 50HZ,Electronic ballasts operating frequency is 20 ~ 50KHZ, lamp luminous efficiency at high frequencies than the frequency increased by 10% , thus the electronic lighting ballasts than magnetic ballasts improve brightness ; another electronic ballast itself less power consumption, If at the same brightness , the use of electronic ballasts than magnetic ballasts saving about 20 to 30% ; which increase the indoor temperature magnetic ballasts work, summer does not need air conditioners, electricity included . Hospital general lighting accounts for about 70% , the use of high- performance electronic ballasts than magnetic ballasts annual savings of 2 to 3 months of electricity , can gradually recovering lighting costs , reduce property operating costs....

 Metal Halide Ballasts  |  High Pressure Sodium Ballasts  |  Fluorescent ballasts  |  Gear Tray
Links: Porcelain lamp socket Mercury Vapor Ballast |  Light bulb socket  

Xml Copyright: @2012-2020 James Lighting Electronic Co.,Ltd